Detail produk:
|
Isolasi: | Xlpe | Voltase: | 0.6/1KV |
---|---|---|---|
Bahan konduktor: | Tembaga | Aplikasi: | Overhead atau bawah tanah, peletakan pipa, peletakan parit, peletakan terowongan, poros vertikal dan |
Tidak ada inti: | 1,2,3,4,5 | Fitur: | Dianjurkan api |
Kabel Daya Terisolasi Multicore XLPE Cu Conductor Fire Proof Kabel dengan Isolasi XLPE EN 60332
Spesifikasi |
Diameter konduktor mm |
Diameter luar kabel yang kira-kira mm |
Berat kabel sekitar kg/km |
||||||
NH |
ZAN |
ZBN |
ZCN |
NH |
ZAN |
ZBN |
ZCN |
||
3 x 16 |
5.0 |
18.9 |
192 |
192 |
19.2 |
659.4 |
713.1 |
719.2 |
680.1 |
3×25 |
6.1 |
22.5 |
22.5 |
22.5 |
22.5 |
974.7 |
1044.6 |
1051.8 |
996.1 |
3x35 |
72 |
24.8 |
24.8 |
24.8 |
24.8 |
1274.1 |
1361.6 |
1369.6 |
1300.0 |
3×50 |
8.4 |
27.9 |
28.3 |
27.9 |
27.9 |
1659.7 |
1806.0 |
1775.4 |
1692.0 |
3×70 |
10.0 |
32.0 |
32.4 |
32.0 |
32.0 |
2320.7 |
2510.1 |
2474.6 |
2362.4 |
3×95 |
12.0 |
36.4 |
36.9 |
36.4 |
36.4 |
3132.4 |
3375.7 |
3334.7 |
3185.7 |
3×120 |
12.2 |
37.5 |
37.9 |
37.5 |
37.5 |
3797.7 |
4053.5 |
4010.8 |
3853.6 |
3×150 |
13.6 |
41.8 |
41.8 |
41.8 |
41.8 |
4681.2 |
4957.1 |
49455 |
4749.1 |
3×185 |
15.2 |
46.3 |
46.3 |
46.3 |
46.3 |
5813.6 |
6154.0 |
6133.9 |
5896.1 |
3×240 |
17.4 |
51.9 |
51.9 |
51.9 |
51.9 |
7519.6 |
7947.6 |
7923.0 |
7621.7 |
3×300 |
19.5 |
572 |
57.2 |
57.2 |
57.2 |
9355.8 |
9847.1 |
9847.1 |
9478.3 |
3×400 |
22.0 |
64.0 |
64.0 |
64.0 |
64.0 |
11858.3 |
12473.0 |
12473.0 |
12009.4 |
4x1.5 |
1.39 |
12.0 |
12.3 |
12.3 |
12.3 |
186.2 |
201.4 |
201.4 |
201.4 |
4x2.5 |
1.76 |
12.9 |
13.2 |
13.2 |
12.9 |
236.7 |
252.8 |
252.8 |
241.3 |
4×4 |
2.22 |
14.0 |
14.3 |
14.3 |
14.0 |
3092 |
327.2 |
327.2 |
314.2 |
4×6 |
2.74 |
15.3 |
15.6 |
15.6 |
15.3 |
402.2 |
422.6 |
422.6 |
407.8 |
4×10 |
4.0 |
18.3 |
18.6 |
18.6 |
18.6 |
588.5 |
634.7 |
640.6 |
607.4 |
4×16 |
5.0 |
21.0 |
21.0 |
21.0 |
21.0 |
845.5 |
900.0 |
906.7 |
863.1 |
4×25 |
6.1 |
24.7 |
24.7 |
24.7 |
24.7 |
1250.8 |
1328.7 |
1336.6 |
1274.7 |
4×35 |
72 |
27.4 |
27.4 |
27.4 |
27.4 |
1643.6 |
1741.3 |
1750.2 |
1672.6 |
4×50 |
8.4 |
30.9 |
31.4 |
30.9 |
30.9 |
2163.3 |
2326.9 |
2292.5 |
2199.4 |
4×70 |
10.0 |
35.5 |
35.9 |
35.5 |
35.5 |
3031.9 |
3243.8 |
3203.9 |
3078.4 |
4×95 |
12.0 |
40.5 |
41.0 |
40.5 |
40.5 |
4098.6 |
4370.6 |
4324.5 |
4158.1 |
4×120 |
12.2 |
41.8 |
42.3 |
41.8 |
41.8 |
4998.3 |
5285.4 |
5236.4 |
5060.6 |
4×150 |
13.6 |
46.4 |
46.4 |
46.4 |
46.4 |
6136.1 |
6444.3 |
6430.9 |
6211.8 |
4×185 |
15.2 |
51.6 |
51.6 |
51.6 |
51.6 |
7649.6 |
8031.2 |
8006.8 |
7741.8 |
4×240 |
17.4 |
57.8 |
57.8 |
57.8 |
57.8 |
9896.6 |
10376.0 |
10346.5 |
10010.5 |
4×300 |
19.5 |
63.7 |
63.7 |
63.7 |
63.7 |
12314.4 |
12861.8 |
12861.8 |
12451.0 |
4×400 |
22.0 |
71.3 |
71.3 |
71.3 |
71.3 |
15606.1 |
16291.7 |
16291.7 |
15774.6 |
5x1.5 |
1.39 |
13.0 |
13.3 |
13.3 |
13.3 |
218.6 |
235.5 |
235.5 |
235.5 |
5x2.5 |
1.76 |
14.0 |
14.3 |
14.3 |
14.0 |
280.8 |
298.8 |
299.5 |
285.8 |
5×4 |
2.22 |
152 |
15.5 |
15.5 |
15.2 |
369.9 |
391.0 |
391.0 |
375.4 |
5×6 |
2.74 |
16.6 |
16.9 |
16.9 |
16.6 |
484.6 |
508.5 |
508.5 |
490.7 |
5 x 10 |
4.0 |
20.4 |
20.4 |
20.4 |
20.4 |
7192 |
769.4 |
776.9 |
7356 |
5×16 |
5.0 |
23.1 |
23.1 |
23.1 |
23.1 |
1031.4 |
1097.7 |
1106.4 |
1052.2 |
5×25 |
6.1 |
27.2 |
27.2 |
27.2 |
27.2 |
1533.7 |
1628.8 |
1637.6 |
1562.1 |
5×35 |
72 |
30.1 |
30.1 |
30.1 |
30.1 |
2021.3 |
2140.4 |
2150.2 |
2055.8 |
5×50 |
8.4 |
34.2 |
34.7 |
34.2 |
34.2 |
2680.5 |
2876.9 |
2838.3 |
2723.7 |
5×70 |
10.0 |
39.3 |
39.8 |
39.3 |
39.3 |
3760.0 |
4014.9 |
3970.1 |
3815.8 |
5×95 |
12.0 |
45.1 |
45.5 |
45.1 |
45.1 |
5107.2 |
5436.4 |
5383.7 |
5178.7 |
5×120 |
12.2 |
46.3 |
46.7 |
46.3 |
46.3 |
6204.7 |
6550.6 |
6495.8 |
6279.6 |
5×150 |
13.6 |
51.6 |
51.6 |
51.6 |
51.6 |
7643.2 |
8020.9 |
8004.6 |
7734.5 |
5×185 |
15.2 |
57.4 |
57.4 |
57.4 |
57.4 |
9525.2 |
9992.5 |
9963.3 |
9636.4 |
5×240 |
17.4 |
64.2 |
64.2 |
64.2 |
64.2 |
12322.0 |
12909.5 |
12874.3 |
12459.9 |
Hubungi kami untuk rincian lebih lanjut
Q.Apa suhu operasi maksimum kabel tahan api konduktor tembaga terisolasi XLPE multi-inti?Aku tidak tahu.
A. Suhu operasi terus menerus biasanya 90°C(IEC 60502-2 sesuai) dengan daya tahan sirkuit pendek hingga250°Cselama 5 detik
Q.Standar keselamatan kebakaran apa yang memenuhi kabel ini?Aku tidak tahu.
A. Mereka bertemuIEC 60332-3-22(penyebaran api di instalasi vertikal) danIEC 60331(durasi ketahanan api, misalnya, 90 menit pada 750°C)
Q.Di mana kabel-kabel ini biasanya dipasang?Aku tidak tahu.
A. Aplikasi kritis termasukbangunan tinggi(sirkuit darurat), terowongan kereta bawah tanah(keperluan asap rendah), danpembangkit listrik(daerah tekanan mekanik tinggi)
T. Apa perbedaan antara versi tahan api dan tahan api?Aku tidak tahu.
A. Kabel tahan api penyebaran api yang lambat(IEC 60332-1), sementara kabel tahan apimenjaga integritas sirkuitsaat kebakaran (IEC 60331)
T. Dapatkah kabel ini digunakan di bawah tanah atau lingkungan laut?Aku tidak tahu.
A. Ya, dengan Perisai kawat baja (SWA)untuk penguburan bawah tanah (IEC 60502-2) ataulapisan bebas halogenuntuk ketahanan korosi laut
P. Bahan konduktor apa saja yang tersedia selain tembaga?Aku tidak tahu.
A. Ada varian inti aluminium (misalnya, konduktor AAAC) tetapi menawarkan Konduktivitas rendah(≈61% tembaga) dan berat yang lebih tinggi
Q. Berapa banyak inti yang bisa dimiliki kabel ini?Aku tidak tahu.
A. Konfigurasi standar termasuk1-5 inti(single-phase untuk tiga-phase sistem), dengan opsi untukkonduktor pengantar tanah konsentrisAku tidak tahu.
Q.Apakah kabel-kabel ini membutuhkan tindakan pencegahan khusus?Aku tidak tahu.
A. Hindarimembungkuk tajam(radius lentur minimum: 12 × diameter kabel) dan Pemanasan berlebihansaat pengelasan di dekat sarung PVC
Kontak Person: Mr. Bai
Tel: +8619829885532